Maintenance 5-161
Installing and Configuring Processor Modules
Figure 5-1 Ejector Levers and Captive Installation Screws
Removing and Replacing the RP, SP, SSP, RSP7000, or RSP7000CI
The RP, SP (or SSP), RSP7000, and RSP7000CI do not support OIR, because they are all required
system components. Removing these boards without first shutting down the system will cause an
abrupt system shutdown and can damage or destroy memory files.
To remove or replace one of these processor modules, first shut down all system power, then follow
the procedures in the following sections, “Removing CxBus Interface Processors” and “Installing
CxBus Interface Processors.”
H1482a
Processor module
slot
a
c
Stop
immediately
on contact
Bottom ejector lever
Captive
installation
screw
Processor
module
carrier guide
b