68-19
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
OL-25340-01
Chapter 68 Performing Diagnostics
Power-On-Self-Test utility did not run during last boot session
___________________________________________________________________________
2) linecard-online-diag ------------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test testing type ------> n/a
Last test execution time ----> Jul 21 2011 20:16:56
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Jul 21 2011 20:16:56
Total failure count ---------> 0
Consecutive failure count ---> 0
Slot Ports Card Type Diag Status Diag Details
---- ----- -------------------------------------- ---------------- ------------
4 4 Sup 7-E 10GE (SFP+), 1000BaseX (SFP) Passed None
Detailed Status
---------------
. = Pass U = Unknown
L = Loopback failure S = Stub failure
P = Port failure
E = SEEPROM failure G = GBIC integrity check failure
Ports 1 2 3 4
. . . .
___________________________________________________________________________
3) stub-rx-errors ------------------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test testing type ------> Health Monitoring
Last test execution time ----> Jul 21 2011 20:25:20
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Jul 21 2011 20:25:20
Total failure count ---------> 0
Consecutive failure count ---> 0
___________________________________________________________________________
4) supervisor-rx-errors ------------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test testing type ------> Health Monitoring
Last test execution time ----> Jul 21 2011 20:25:20
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Jul 21 2011 20:25:20
Total failure count ---------> 0
Consecutive failure count ---> 0
Note To ensure that the maximum number of ports are tested, ensure that both supervisor engines are present
on power-up.