12-4
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
OL-25340-01
Chapter 12 Environmental Monitoring and Power Management
About Environmental Monitoring
The following example illustrates how to display the environment condition on WS-C4500X-32 with a
Supervisor Engine 7-E. The thresholds appear within parentheses.
Switch> show environment
no temperature alarms
Module Sensor Temperature Status
------+--------------------------+--------------------+------------
1 XPP 42C (80C,90C,100C) ok
1 VFE 47C (80C,90C,100C) ok
1 CPU 46C (80C,90C,100C) ok
1 FPGA 50C (80C,90C,100C) ok
1 Stub A 34C (80C,90C,100C) ok
1 Stub B 35C (80C,90C,100C) ok
2 Air inlet 31C (80C,90C,100C) ok
2 Air outlet 36C (80C,90C,100C) ok
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 none -- -- -- --
PS2 PWR-C49X-750AC-R AC 750W good good n.a.
Power supplies needed by system : 1
Power supplies currently available : 1
Chassis Type : WS-C4500X-32
Power consumed by backplane : 0 Watts
Switch Bandwidth Utilization : 0%
Supervisor Led Color : Green
Module 1 Status Led Color : Green
Module 2 Status Led Color : Green
Beacon Led Status : off
Fan trays needed by system : 4
Fan trays currently available : 5
Chassis fan tray direction : FrontToBack
Fantray 1 : dir : FrontToBack status : Good
Fantray 2 : dir : FrontToBack status : Good
Fantray 3 : dir : FrontToBack status : Good
Fantray 4 : dir : FrontToBack status : Good
Fantray 5 : dir : FrontToBack status : Good
Fantray removal timeout : 30
Power consumed by Fantray : 30 Watts
Switch>
Emergency Actions
Catalyst 4500 chassis can power down a single card, providing a detailed response to over-temperature
conditions on line cards. However, the Catalyst 4500 chassis cannot safely operate when the temperature
of the supervisor itself exceeds the critical threshold. The supervisor engine turns off the chassis’ power