12-11
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
OL-25340-01
Chapter 12 Environmental Monitoring and Power Management
Power Management
2 6 1000BaseX (GBIC) WS-X4306 00000110
3 18 1000BaseX (GBIC) WS-X4418 JAB025104WK
5 0 Not enough power for module WS-X4148-FX-MT 00000000000
6 48 10/100BaseTX (RJ45) WS-X4148 JAB023402RP
M MAC addresses Hw Fw Sw Status
--+--------------------------------+---+------------+----------------+---------
1 005c.9d1a.f9d0 to 005c.9d1a.f9df 0.5 12.1(11br)EW 12.1(20020313:00 Ok
2 0010.7bab.9920 to 0010.7bab.9925 0.2 Ok
3 0050.7356.2b36 to 0050.7356.2b47 1.0 Ok
5 0001.64fe.a930 to 0001.64fe.a95f 0.0 PwrDeny
6 0050.0f10.28b0 to 0050.0f10.28df 1.0 Ok
Switch#
Limitation 2
Certain configurations on the Catalyst 4507R and Catalyst 4510R chassis exceeds the maximum amount
of data power available. These configurations include the combination of the follow PIDs:
• 7-slot configuration
• Chassis: WS-C4507R-E, WS-C4510R-E
• Dual supervisor engines: WS-X45-Sup6-E and WS-X45-Sup6L-E
• One or more: WS-X4448-GB-RJ45 or WS-X4148-FX-MT
To maximize the 10/100/1000 port density of 7- and 10- slot chassis, install WS-X4548-GB-RJ45 line
cards instead of WS-X4448-GB-RJ45 line cards. If WS-X4448-GB-RJ45 line cards are required, two
options are available:
• Option 1
Only four line card slots can be used on the Catalyst 4507R and six line card slots on the Catalyst
4510R chassis.
• Option 2
When all slots are required, only one WS-X4448-GB-RJ45 line card can be used.
To maximize the 100-BASE-FX port density of 7- and 10- slot chassis, install WS-4248-FE-SFP line
cards with FX optics instead of WS-X4148-FX-MT line cards. If WS-X4148-FX-MT line cards are
required, two options are available:
• Option 1
Only four line card slots can be used on the Cat4507R and six line card slots on the Catalyst 4510R
chassis.
• Option 2
When all slots are required only one WS-X4448-GB-RJ45 line card can be used.
Configuring Redundant Mode on a Catalyst 4500 Series Switch
By default, the power supplies in a Catalyst 4500 series switch are set to operate in redundant mode. To
effectively use redundant mode, follow these guidelines:
• Use two power supplies of the same type.
• If you have the power management mode set to redundant mode and only one power supply
installed, your switch accepts the configuration but operates without redundancy.