12-17
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
OL-25340-01
Chapter 12 Environmental Monitoring and Power Management
Power Management
If you have max inputs 3 configured with four “good” (220 V) inputs and you limit the user to 5500 W
instead of 7600 W and one subunit fails or is powered off, you have three quality inputs providing 5500
W and the chassis is powered at the same rate as it was prior to the failure event:
Switch# configuration terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)# power redundancy combined max inputs 3
Switch(config)# end
Switch#
14:32:01: %SYS-5-CONFIG_I: Configured from console by console
Here is the output of the show power command prior to invoking this feature:
Switch# show power
sh power
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-4200ACV AC 4200W good good good
PS1-1 110V good
PS1-2 110V good
PS2 PWR-C45-4200ACV AC 4200W good good good
PS2-1 110V good
PS2-2 110V good
Power supplies needed by system : 1
Power supplies currently available : 2
Power Summary Maximum
(in Watts) Used Available
---------------------- ---- ---------
System Power (12V) 140 1360
Inline Power (-50V) 0 1850
Backplane Power (3.3V) 0 40
---------------------- ---- ---------
Total 140 (not to exceed Total Maximum Available = 2100)
Here is the output after invoking this feature. The combined mode was indicated before
Power supplies needed = 2 in the output of the show power command, combined mode is now indicated
by the phrase Power supplies needed by system: 2 Maximum Inputs = 3.
Switch# show power
sh power
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-4200ACV AC 4200W good good good
PS1-1 110V good
Command Purpose
Step 1
Switch# configure terminal
Enters configuration mode.
Step 2
Switch(config)# power redundancy combined max
inputs {2 | 3}
Limits the power usage to two or three
inputs.
Note The maximum inputs part of the
command is ignored by all power
supplies other than the 4200 W AC or
6000 W AC.
Step 3
Switch(config)# end
Exits configuration mode.