EasyManua.ls Logo

Cisco D9824 - Page 336

Cisco D9824
416 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Service and Maintenance
314
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
FPGA
Temperature
Alarm
Set
Temperature over
Alarm threshold
Cause: Room
temperature too
high, or air flow is
blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.
FPGA
temperature is
above safe
operating
range.
Major
30000
FPGA
Temperature
Alarm
Clear
Temperature
normal
Major
30000
ASI Out Status
Set
ASI Overflow.
Output Muted.
Reduce content.
Cause: Uplink
settings may have
changed since
setup of the unit.
Variable Bit
Rate/Statmuxed
streams may be in
use.
Remedy: Increase
the output rate,
drop unreferenced
content in DPM
Options, and/or
drop programs
not needed for
downstream
devices. Contact
your (uplink)
service provider to
verify the
expected bit rate
settings.
Current
transport rate
exceeds
configured rate
for ASI output.
Output has
been muted to
protect
downstream
devices.
Minor
34000
ASI Out Status
Clear
ASI Output
Restored
Minor
34000

Table of Contents

Related product manuals