Indicates the number of non-
encrypted Addressable Data Packets
successfully processed. Ideally, the
ADP Non-Enc Pass and ADP Non-
Enc Total numbers should be
identical.
Indicates the total number of non-
encrypted Addressable Data Packets
received. Ideally, the ADP Non-Enc
Pass and ADP Non-Enc Total
numbers should be identical.
Select to clear the Addressable Data
Packet counters: ADP Enc Pass, ADP
Enc Total, ADP Non- Enc Pass and
ADP Non-Enc Total. These values
are also reset whenever the receiver
is turned on, reset or power-cycled.
Sets the Basic Interoperable
Scrambling System (BISS) mode for
the receiver. All channels assigned to
a PE identified as BISS CA-
controlled in the PMT will be
decrypted.
If BISS Mode is Mode 1, enter the
session word.
12-character password. Once
entered, it cannot be viewed and
it is only displayed as asterisks
(*).
Contact your program provider
for the session word.
If BISS Mode is Mode E, enter the
encrypted session word.
16-character password. Once
entered, it cannot be viewed and
it is only displayed as asterisks
(*).
Contact your program provider
for the session word.
If BISS Mode is Mode E, enter the
injected ID.
14-character password. Once
entered, it cannot be viewed and
it is only displayed as asterisks
(*).
Contact your program provider
for the session word.