307
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
NIT Retune
Recovery
Set
NIT Retune
Recovery
Cause: NIT is
configured
incorrectly on the
uplink. It fails to
lock/acquire the
signal.
Remedy: Contact
your PNC uplink
administrator to
correct the invalid
NIT on the uplink
so that the signal
can be locked and
acquired. The
administrator
should also ensure
that the uplink
configuration
matches the NIT.
An invalid
NIT is
received and
the unit fails
to
lock/acquire
the NIT signal.
Major
980
NIT Retune
Recovery
Clear
Alarm cleared
–
The error is
cleared when
another valid
NIT is
received and
the signal is
locked and
acquired, or
the incorrect
configuration
is resolved.
Major
980
Warnings
Warning
Message
Type
Message
Cause/Remedy
Description
ID
Transcoding
Condition
Set
Transcoding
Error: Decoder
timeout
Cause: Possible software
issue.
Remedy: Clear alarms,
reset the unit, and notify
Cisco Services if the
problem persists.
The transcoder has
lost connection with
the decoder.
39500