Chapter 4 Front Panel Operation
Setup Menu: Alarm/Warning
To view the Alarm/Warning menu from the Main menu, press the RIGHT arrow
key once and then the SELECT key to reach the Setup menu. Then press the RIGHT
arrow key seven times and the SELECT key to view the Alarm/Warning menu.
The Alarm/Warning menu allows you to browse the active alarms and warnings,
and set whether the output will be disabled in the event of an alarm. This menu has
the following structure:
FP Alarm Reminder Alarm Vid Cutoff
Disable Disable
i
s
Alarm/Warning
System Alarm Name Enb Rly Trp
Loss Of Signal Yes Yes Yes
i
s
System Warning Name Enb Rly Trp
PMT Timeout Yes Yes Yes
i
s
Select whether to display
alarms and warnings on the
front panel. The alarm indicator
will intermittently flash in the
lower line, if enabled.
Select whether the video output
is cut off if any enabled alarm is
active on the receiver. When
video is cut off, there will be no
horizontal or vertical
synchronization on the output.
This is useful for downstream
redundancy switching by
detecting a loss of video signal.
Note: This function also exists
under Setup: Services: Video.
Enable or Disable
The default is Disable.
System
Alarm/Warning
Name
Displays the alarm or warning
to configure.
Select whether the current
alarm is enabled or disabled. If
the alarm is disabled, the Rly
and Trp settings are ignored