Chapter 6 Service and Maintenance
306
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
PE <n>: CA
System Error
Set
No PowerVU
support
Cause: The current
channel assigned to
this Program Entry
is scrambled using
an unsupported
CA System.
Remedy: Check to
ensure that the
proper channel is
assigned to this
Program Entry.
CA System
present in the
currently
selected
channel
cannot be
descrambled
due to no
PowerVu ISE
support.
Minor
93000-93031
PE <n>: CA
System Error
Set
No Matching CAM
Cause: The current
channel assigned to
this Program Entry
is scrambled using
an unsupported
CA System.
Remedy: Check to
ensure that the
proper channel is
assigned to this
Program Entry.
CA System
present in the
currently
selected
channel
cannot be
descrambled
due to no
PowerVu ISE
support.
Minor
93000-93031
PE <n>: CA
System Error
Clear
Fault cleared
–
–
Minor
93000-93031
D/R in
Progress
Set
Disaster declared
Cause: One or more
of the following is
detected: RF lock
loss, unstable RF
signal, and/or
transport loss (RF
locked, but no
transport stream
packet received)
Remedy: A valid
signal.
A disaster is
detected.
Major
970
D/R in
Progress
Reset
No disaster
–
Disaster
recovery
feature is
cleared with a
valid signal.
Major
970