Chapter 6 Service and Maintenance
292
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
LMI setup
Set
LMI SDRAM
exhaust test failed
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
DDR RAM on
LMI bus not
working.
Major
22000
LMI setup
Clear
LMI Video SDRAM
exhaust test passed
DDR RAM on
LMI bus OK.
Major
22000
Param Storage
Set
DB NVS flushing
ignored
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
Non-volatile
storage system
failed to
update fully.
Major
23000
Param Storage
Set
RAM flush to NVS
failed
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
Non-volatile
storage system
failed to
update fully.
Major
23000
Param Storage
Set
DB Factory Reset in
progress
Cause: Standard
operation.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
Non-volatile
storage system
operation in
progress.
Major
23000
Param Storage
Set
DB Total Reset in
progress
Cause: Standard
operation.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
Non-volatile
storage system
operation in
progress.
Major
23000

Table of Contents