295
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
Flash Storage
Set
RECORD: sector
setup check error,
erasing sector
Cause: Hardware
issue.
Remedy:
Clear alarms, reset
the unit, and notify
Cisco Services if the
problem persists.
NVS
Corruption,
and loss of
sector data
Major
24000
Flash Storage
Clear
RECORD: init done
Major
24000
LNB PS
Set
LNBPS: No Load
Cause: Possible
wiring or hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
LNB power
overload
Minor
25000
LNB PS
Set
LNBPS: Over
Temperature
Cause: Possible
wiring or hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
LNB power
overload
Minor
25000
LNB PS
Set
LNBPS: Over
Loaded
Cause: Possible
wiring or hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
LNB power
overload
Minor
25000
LNB PS
Set
LNBPS: Short
Circuit
Cause: Possible
wiring or hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if the
problem persists.
LNB power
overload
Minor
25000
LNB PS
Clear
LNBPS: Normal
LNB power
OK
Minor
25000