EasyManuals Logo

Cisco D9858 User Manual

Cisco D9858
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #320 background imageLoading...
Page #320 background image
Chapter 6 Service and Maintenance
298
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
DL: TEB
Comms Failure
Set
TMB-TEB comms
failure
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco Services if
problem persists.
Internal
communicatio
n failure.
Major
27500
DL:NVS Flash
Failure
Set
APP5514 Flash
Write Failed
Cause: Possible
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if problem
persists.
Failed to read
or write flash
memory
Major
27600
DL:NVS Flash
Failure
Set
APP/SAT7109/PP
C CRC/Write has
Failed
Cause: Possible
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if problem
persists.
Failed to read
or write flash
memory
Major
27600
DL:NVS Flash
Failure
Set
TEB Flash Write
Failed
Cause: Possible
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if problem
persists.
Failed to read
or write flash
memory
Major
27600
Temperature
Alarm
Set
Temperature over
Alarm threshold
Cause: Room
temperature too
high, or air flow is
blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air flow
to device.
Temperature
is above safe
operating
range.
Major
28000