Chapter 6 Service and Maintenance
300
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
TEB ENC1
Temper. Alarm
Set
Temperature over
Alarm threshold
Cause: Room
temperature is too
high, or air flow is
blocked.
Remedy: Check the
openings on the
front and rear
panels for blockage,
assess the room
temperature.
Lower the room
temperature or
improve air flow to
the device.
TEB encoder 1
temperature is
above the safe
operating
range.
Major
32000
TEB ENC1
Temper. Alarm
Clear
Temperature
normal
TEB encoder 1
temperature is
within the safe
operating
range.
Major
32000
TEB ENC2
Temper. Alarm
Set
Temperature over
Alarm threshold
Cause: Room
temperature is too
high, or air flow is
blocked.
Remedy: Check the
openings on the
front and rear
panels for blockage,
assess the room
temperature.
Lower the room
temperature or
improve air flow to
the device.
TEB encoder 2
temperature is
above the safe
operating
range.
Major
33000
TEB ENC2
Temper. Alarm
Clear
Temperature
normal
TEB encoder 2
temperature is
within the safe
operating
range.
Major
33000