Chapter 6 Service and Maintenance
302
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
Boot Host
Set
KB not accessible
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
KB is not
detected by
Boot code.
Major
36000
Boot Host
Set
LCD not connected
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
LCD is not
detected by
Boot code.
Major
36000
Boot Host
Set
FLASH Not Found
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Flash memory
not detected.
Major
36000
Boot Host
Set
EMI SDRAM Test
Failed
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
RAM Failure -
memory
testing failed.
Major
36000
Boot Host
Set
BOOT Invalid
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Boot SW
cannot be read
from memory
correctly.
Major
36000
Boot Host
Set
APP Invalid
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Application
SW cannot be
read from
memory
correctly.
Major
36000