Chapter 6 Service and Maintenance
316
Warning
Message
Type
Message
Cause/Remedy
Description
ID
NIT timeout #
Set
NIT is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Network Information
Table.
75000
NIT timeout #
Clear
NIT fault cleared
75000
CAT timeout #
Set
CAT timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Conditional Access
Table was never
received.
76000
CAT timeout #
Set
CAT is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Conditional Access
Table.
76000
CAT timeout #
Clear
CAT fault cleared
76000
DRT timeout #
Set
DRT # timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Disaster Recovery
Table was never
received.
77000