D15335.02 Cisco TelePresence MX700 and MX800 API Reference Guide CE8.0, FEBRUARY 2016.
Copyright © 2016 Cisco Systems, Inc. All rights reserved. 166
Cisco TelePresence MX700 and MX800
API Reference Guide
SystemUnit status
xStatus SystemUnit
Shows the top level overview of the system unit status.
xStatus SystemUnit Hardware Module SerialNumber
Shows the serial number of the hardware module in the codec.
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Module SerialNumber
*s SystemUnit Hardware Module SerialNumber: "FTT123456A1"
** end
xStatus SystemUnit Hardware Monitoring Fan [n] Status
The feedback shows the speed (rpm) for the specified fan.
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Monitoring Fan 1 Status
*s SystemUnit Hardware Monitoring Fan 1 Status: "locked on 1096 rpm"
** end
xStatus SystemUnit Hardware Temperature
Shows the current maximum temperature (degree Celsius) measured in the codec/system.
Value space of the result returned:
String
Example:
xStatus SystemUnit Hardware Temperature
*s SystemUnit Hardware Temperature: "64.0"
** end
xStatus SystemUnit Notifications Notification [n] Text
Lists text related to important system notifications. Notifications are issued e.g. when a system
was rebooted because of a software upgrade, or when a factory reset has been performed.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Value space of the result returned:
String
Example:
xStatus SystemUnit Notifications Notification 1 Text
*s SystemUnit Notifications Notification 1 Text: "OK"
** end
xStatus SystemUnit Notifications Notification [n] Type
Lists the system notification types. Notifications are issued e.g. when a system is rebooted
because of a software upgrade, or when a factory reset is performed.
FactoryResetOK: This value is returned after a successful factory reset.
FactoryResetFailed: This value is returned after a failed factory reset attempt.
SoftwareUpgradeOK: This value is returned after a successful software upgrade.
SoftwareUpgradeFailed: This value is returned after a failed software upgrade attempt.
RebootRequired: This value is returned when a reboot is required.
Other: This value is returned for any other notifications.
All the notifications can be removed from the list by issuing the xCommand SystemUnit
Notifications RemoveAll command.
Value space of the result returned:
FactoryResetOK, FactoryResetFailed, SoftwareUpgradeOK, SoftwareUpgradeFailed,
RebootRequired, Other
Example:
xStatus SystemUnit Notifications Notification 1 Type
*s SystemUnit Notifications Notification 1 Type: SoftwareUpgradeOK
** end
Introduction
About the API
xConfiguration
Appendices
xCommand
xStatus

xStatus

Table of Contents

Other manuals for Cisco TelePresence MX200 G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco TelePresence MX200 G2 and is the answer not in the manual?

Cisco TelePresence MX200 G2 Specifications

General IconGeneral
Resolution1920 x 1080
Network10/100/1000 Ethernet
Product TypeVideo conferencing system
Display Size42 in
CameraPrecisionHD 1080p Camera
CodecCisco TelePresence Codec
Video InputsHDMI, DVI-I
Video OutputsHDMI
ControlCisco Touch 10
Video StandardsH.264
ConnectivityHDMI
Codec SupportH.264
Resolution (fps)1080p30