D15335.02 Cisco TelePresence MX700 and MX800 API Reference Guide CE8.0, FEBRUARY 2016.
Copyright © 2016 Cisco Systems, Inc. All rights reserved. 72
Cisco TelePresence MX700 and MX800
API Reference Guide
xConfiguration Proximity Services ContentShare FromClients
Enable or disable content sharing from Proximity clients. When this setting is enabled, you can
share content from a Proximity client wirelessly on the video system, e.g. share your laptop
screen. This service is supported by laptops (OS X and Windows). Proximity Mode must be On
for this setting to take any effect.
Requires user role: ADMIN
Default value: Disabled
USAGE:
xConfiguration Proximity Services ContentShare FromClients: FromClients
where
FromClients
: Enabled/Disabled
Enabled: Content sharing from a Proximity client is enabled.
Disabled: Content sharing from a Proximity client is disabled.
xConfiguration Proximity Services ContentShare ToClients
Enable or disable content sharing to Proximity clients. When enabled, Proximity clients will
receive the presentation from the video system. You can zoom in on details, view previous
content and take snapshots. This service is supported by mobile devices (iOS and Android).
Proximity Mode must be On for this setting to take any effect.
Requires user role: ADMIN
Default value: Disabled
USAGE:
xConfiguration Proximity Services ContentShare To Clients: ToClients
where
ToClients
: Enabled/Disabled
Enabled: Content sharing to a Proximity client is enabled.
Disabled: Content sharing to a Proximity client is disabled.
SerialPort configuration
xConfiguration SerialPort Mode
Enable/disable the serial port (COM port).
Requires user role: ADMIN
Default value: On
USAGE:
xConfiguration SerialPort Mode: Mode
where
Mode
: Off/On
Off: Disable the serial port.
On: Enable the serial port.
xConfiguration SerialPort BaudRate
Define the baud rate (data transmission rate, bits per second) for the serial port. The default
value is 115200.
Other connection parameters for the serial port are: Data bits: 8; Parity: None; Stop bits: 1; Flow
control: None.
Requires user role: ADMIN
Default value: 115200
USAGE:
xConfiguration SerialPort BaudRate: BaudRate
where
BaudRate
: 9600/19200/38400/57600/115200
Set a baud rate from the baud rates listed (bps).