EasyManuals Logo

Cisco TelePresence SX80 User Manual

Cisco TelePresence SX80
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
D15107.0 5 Codec SX80 API Reference Guide TC7.3, OCTOBER 2015. Copyright © 2015 Cisco Systems, Inc. All rights reserved. 213
Cisco TelePresence SX80 API Reference Guide
xStatus SystemUnit State Subsystem Application
Shows the status of the sub system application.
Initialized: The sub-system application is initialized.
Initializing: The sub-system application is initializing.
Value space of the result returned:
<Initialized/Initializing>
Example:
xStatus SystemUnit State Subsystem Application
*s SystemUnit State Subsystem Application: Initialized
** end
xStatus SystemUnit ContactInfo
Returns the system's active contact information. This is the address which is used to reach this
system.
Value space of the result returned:
<String>
Example:
xStatus SystemUnit ContactInfo
*s SystemUnit ContactInfo: "firstname.lastname@company.com"
** end
xStatus SystemUnit ContactName
Returns the system's active contact name. The result depends on which protocol, if any, the system
is registered on. Unlike Contact Info, Contact Name is not configurable and is automatically set by
the system.
Value space of the result returned:
<String>
Example:
Not registered to a protocol
xStatus SystemUnit ContactNa me: "192.0.2.0"
Example 2: Registered on SIP
xStatus SystemUnit ContactNa me: "1234@192.0.2.0"
xStatus SystemUnit Notifications Notification [n] Type
Lists the system notification types. Notifications are issued e.g. when a system is rebooted because
of a software upgrade, or when a factory reset is performed.
FactoryResetOK: This value is returned after a successful factory reset.
FactoryResetFailed: This value is returned after a failed factory reset attempt.
SoftwareUpgradeOK: This value is returned after a successful software upgrade.
SoftwareUpgradeFailed: This value is returned after a failed software upgrade attempt.
RebootRequired: This value is returned when a reboot is required.
Other: This value is returned for any other notifications.
All the notifications can be removed from the list by issuing the xCommand SystemUnit Notifications
RemoveAll command.
Value space of the result returned:
<FactoryResetOK, FactoryResetFailed, SoftwareUpgradeOK, SoftwareUpgradeFailed,
RebootRequired, Other>
Example:
xStatus SystemUnit Notifications Notification 1 Type
*s SystemUnit Notifications Notification 1 Type: SoftwareUpgradeOK
** end
xStatus SystemUnit Notifications Notification [n] Text
Lists text related to important system notifications. Notifications are issued e.g. when a system was
rebooted because of a software upgrade, or when a factory reset has been performed.
All the notifications can be removed from the list by issuing the xCommand SystemUnit Notifications
RemoveAll command.
Value space of the result returned:
<String>
Example:
xStatus SystemUnit Notifications Notification 1 Text
*s SystemUnit Notifications Notification 1 Text: "OK"
** end
Contents
Introduction
About the API
xConfiguration
Appendices
xCommand
xStatusxStatus

Table of Contents

Other manuals for Cisco TelePresence SX80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco TelePresence SX80 and is the answer not in the manual?

Cisco TelePresence SX80 Specifications

General IconGeneral
Maximum frame rate60 fps
Supported video modes720p, 1080p
Video formats supportedH.261, H.262, H.263, H.264, H.265
Supported graphics resolutions1280 x 720 (HD 720), 1920 x 1080 (HD 1080)
Voice codecsG.711, G.722, G.722.1, G.729ab
Noise reductionYes
HDMI ports quantity5
DVI-D ports quantity1
USB 2.0 ports quantity2
Product colorSilver
Rack capacity1U
Number of persons0 person(s)
Analog signal format systemNTSC, PAL
Security algorithmsHTTPS, SSH
Ethernet LAN data rates10, 100, 1000 Mbit/s
Supported network protocolsSIP, H.323, ISDN, TCP/IP, DHCP, QoS
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 90 %
Sensor type-
Image sensor size- \
Weight and Dimensions IconWeight and Dimensions
Depth309.8 mm
Width442 mm
Height44 mm
Weight3650 g

Related product manuals