3 Interface 37
*1 Codes for errors and Corresponding Errors of LS-R700
Error: 23 Mastering Error
Error: 22 Stop Valves Closed
Error: 3 Test Pressure Error
Error: 2 PS Output Out of Range
Error: 11 ~ 16 Air Operated Valve Error
Error: 51 Lo Battery SRAM Error
*2 Fixed to 0.2 (s) for the pneumatic circuits those have the stage and 0.0[s] for those don’t have the stage.
*3 Leak Unit, Test Pressure Unit, K(Ve) Unit and Compensation Type
Leak Unit
00: Pa, 01: kPa, 02: mmH
2
O, 03: inH
2
O, 04: mmHg, 05: mL/s, 06: mL/min,
07: in
3
/min, 08: in
3
/d, 09: L/min, 10: Ft
3
/h, 11: Pam
3
/s, 12: E-3·m
3
/s,
13: Pa/s, 14: Pa/min, 15: *Pa/s, 16: *Pa/min
Test Pressure Unit
00: kPa, 01: MPa, 02: PSI, 03: kg/cm
, 04: bar, 05: mbar, 06: mmHg,
00: mL, 01: L, 02: in
3
, 03: ft
3
Comp Type
00: No Compensation, 01: Drift Compensation / Fixed Compensation,
02: Mastering Compensation / Drift & Mastering Compensation
P Format
D Format
ig: 0001, -9.50, -9.50, +.000, -9.50, 96.1, CHG, 00 CR
Comp Value +.000
ΔP -9.50
CH# 00
Refer to 2.6 Printer.
Refer to “
6
6 SETUP” for the details.