CHAMP-AV8 (VPX6-462) HARDWARE USERS MANUAL CURTISS-WRIGHT
2-2 PROPRIETARY 826448 VERSION 5 MARCH 2015
UNPACKING THE CARD
To unpack the card from its protective package, follow these steps:
1. Unpack the Circuit Card Assembly from the shipping carton in a suitable work area. If
the shipping carton appears to be damaged, request that an agent of the shipper or car-
rier be present during unpacking and inspection.
2. Find the packing list. Make sure all the items on the list are present.
3. Save the packing material for storing or reshipping the card.
4. If your CHAMP-AV8 was shipped with an XMC module installed, make sure it is firmly
attached to the basecard.
CHECKING HARDWARE REQUIREMENTS
Make sure the various hardware requirements summarized beginning on page 2-2 have been
met before you install the CHAMP-AV8.
CHASSIS REQUIREMENTS
The air-cooled (VPX6-462-A) Level 000 and Level 100 CHAMP-AV8 cards are designed to be
installed in an air-cooled chassis.
Conduction-cooled Level 100 and Level 200 (VPX6-462-C) CHAMP-AV8 cards are designed to
be installed in a conduction-cooled chassis.
BACKPLANE REQUIREMENTS
The CHAMP-AV8 boards are designed to be used with the VITA 65 backplanes with the
following Slot and Module profiles:
Slot Profile: SLT6-PAY-4F1Q2U2T-12.2.1
Module Profile: MOD6-PAY-4F1Q2U2T-12.2.1-11/12
Warning
To avoid personal injury or damage to this Circuit Card Assembly, disconnect the
chassis from its power source before removing or installing any cards.
This Circuit Card Assembly uses components that are sensitive to electrostatic dis-
charges. It must be kept sealed in its conductive package until just before you in-
stall it. Remove the card from its protective package only at a grounded
workstation while wearing an approved grounding wrist strap. Avoid touching any
metal contacts on the card. Static discharges can damage integrated circuits.
Cross Reference
Refer to the Ruggedization Capabilities described on http://www.cwcdefense.com/ for more
information.