EasyManua.ls Logo

Curtiss-Wright CHAMP-AV8 - Cable Requirements; Figure 2.1: CBL-462-FPL-000 (CHAMP-AV8 Standard Front Panel Cable Assembly)

Default Icon
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAMP-AV8 (VPX6-462) HARDWARE USERS MANUAL CURTISS-WRIGHT
2-6 PROPRIETARY 826448 VERSION 5 MARCH 2015
CABLE REQUIREMENTS
A Front Panel interface cable is available to support the CHAMP-AV8. This cable is identified as:
CBL-462-FPL-000 (CHAMP-AV8 Standard Front Panel Cable Assembly - see Figure 2.1)
CBL-462-FPL-000
(903075-000)
Figure 2.1 shows a cable drawing of the CHAMP-AV8 Standard Front Panel Cable Assembly
(CBL-462-FPL-000). The cable assembly provides access to the following CHAMP-AV8 signals:
USB A (J1); RS-232 Port A0 (J2); RS-232 Port B0 (J3); Ethernet Port 0 (J4); Ethernet Port 1
(J5); Reset Switch (SW1).
Figure 2.1: CBL-462-FPL-000 (CHAMP-AV8 Standard Front Panel Cable
Assembly)
Caution
The CHAMP-AV8 front panel cable is different than that used on the CHAMP-AV6, even
though the physical front panel connector is the same. To use the CHAMP-AV8 front panel,
the user must employ CBL-462-FPL-000.
J1
J2
J3
J4
J5
SW1 RESET
36" +/- 2"
Add heatshrink as
Required to secure adapter
Add 903075-000
assembly number label
and associated revision.
Located anywhere on this
branch.
Add 2" transparent
heatshrink sleave (0.5"
diameter) for CWC lable
(part # 172249-503)
application under the
heatshrink. Leave
heatshrink loose, ie. do not
heat.
P1
18" +/- 1"
POS.1POS.14
POS.13POS.26
Add label near connector
with reference designator
and function per parts list
table comments.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents