Interleaved 2 of 5 (I 2 of 5)
Product Reference Guide 159
ENTER/EXIT PROGRAMMING MODE
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the
minimum label length if in Variable Length Mode, or the first fixed length if in Fixed
Length Mode. The length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters in increments of two. See Set Length 1 on
page 268 for more detailed programming instructions.
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
06 = Length 1 is 6 Characters