IATA
Product Reference Guide 209
ENTER/EXIT PROGRAMMING MODE
IATA
The following options apply to the IATA symbology.
IATA Enable/Disable
Enables/Disables the ability of the reader to decode IATA labels.
IATA Check Character Transmission
Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
$CIAEN00
IATA = Disable
$CIAEN01
IATA = Enable
DEFAULT
$CIACT00
IATA Check Character Transmission = Disable
$CIACT01
IATA Check Character Transmission = Enable
DEFAULT

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2100 and is the answer not in the manual?

Datalogic QuickScan Lite QW2100 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength650 nm
Sensor typeLaser
Read rate (max)400 reads/s
Yaw reading angle-70 - 70 °
Tilt reading angle-45 - 45 °
Pitch reading angle-65 - 65 °
Linear (1D) barcodes supportedEAN 5, EAN-13, EAN-8, GS1-128 (UCC/EAN-128)
2D (matrix & stacked) barcodes supportedNot supported
Standard interfacesUSB
Connectivity technologyWired
Input voltage5 V
Power consumption340 mA
Power source typeDC
Product colorBlack
Housing material-
International Protection (IP) codeIP42
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth65 mm
Width170 mm
Height70 mm
Weight119 g