EasyManuals Logo

Dell EMC ML3 User Manual

Dell EMC ML3
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
Table 35. Main error events (continued)
Event Code Message Text and Description Details and Solution
2009 Library test failed due to
accessor problem.
v Review test requirements and retry the test.
v If the test continues to fail check for accessor obstructions or
other accessor problems.
v For proper operation, the accessor must be able to reach the
bottom of the library. Verify that no obstructions are at the
bottom of the library or on the bottom cover of the library in
the path of the accessor.
1. To check for obstructions at the bottom of the library, first
power off the library by pressing Power for 5 seconds and
select the Default Park location.
2. When the library is powered off, remove the left magazine of
the lowest library module, and verify that the entire area of
the bottom cover is free of any objects that might obstruct the
accessor's path.
3. After any obstructions are cleared, replace the magazine,
power the library on, and after the library finishes
initialization and inventory, verify that no further critical
events were generated.
2010 Library test failed due to
spooling mechanism defect.
Ensure that the spooling mechanism is fully seated in the base
module and installed correctly to the accessor assembly.
2012 Multiple bottom covers
detected.
Remove all bottom covers except for the bottom module in the
library.
2013 Multiple top covers detected. Remove all top covers except for the top module in the library.
2014 Bottom cover is missing. Install the bottom cover on the bottom module of the library,
also check the module interconnect cabling and module power
cabling. If the base module cannot detect both a top and bottom
cover, the accessor does not move.
2015 Top cover is missing. Install the top cover on the top module of the library. Also, check
the module interconnect cabling and module power cabling. If
the base module cannot detect both a top and bottom cover, the
accessor does not move.
2016 Unit to unit not locked. Ensure that the alignment mechanism is engaged in every
module that is above another module in the library.
2017 Communication error during
stack discover process.
v Ensure that all modules are powered and have the
interconnect cable properly attached.
v Ensure that the module alignment locks (at the rear of
module) are in the correct positions.
2021 Database access error. Restore a configuration backup and run a power cycle.
2022 Drive was hot-removed. Reinsert the removed drive at the same position as it was
removed.
2023 Internal software error. Check for a new system software version for upgrade.
2024 Unhandled Exception Check for a new system software version for upgrade.
80 Dell EMC ML3 Tape Library: User's Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC ML3 and is the answer not in the manual?

Dell EMC ML3 Specifications

General IconGeneral
Number of Drives1
CategoryTape Library
Drive TechnologyLTO
Humidity20% to 80% (non-condensing)
Drive TypeLTO Ultrium
Maximum Capacity15 TB (compressed)
Interface6Gb/s SAS
Max Data Transfer Rateup to 750 MB/s (with compression)
Operating Temperature10°C to 35°C
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)