Table 35. Main error events (continued)
Event Code Message Text and Description Details and Solution
2076 I2C bus signals invalid.
v Remove all drive canisters of the affected chassis and restart
the library.
v If the problem persists, replace the chassis. If not, add one
drive after the other until the problem comes back.
v Replace the last drive that was added before it failed again.
2077 Failed to store Calibration Data
to Chassis.
Restart or power cycle system.
2079 Could not upgrade bar code
reader firmware.
Restart the library and if the error persists, replace the accessor.
2080 Cartridge lost while inserting it
into slot/drive.
Check the source/destination element and ensure that no
obstructions are in the pathway of the accessor.
2087 Error accessing the backplane
flash memory.
v Restart the library and if the error persists, replace the chassis.
v Before the chassis is replaced, ensure that you remove all of
your tape cartridges.
v If magazines need to be removed to get access to the tape
cartridges, first power down the device and then manually
release each magazine. Only one magazine must be opened at
a time.
2089 Incompatible accessor assembly
detected.
An incompatible accessor was detected. The accessor was not
powered on to avoid damage of the library. Power off the library
and replace the accessor with a compatible version.
2092 Locking the accessor assembly
failed during Power Down
process
Power up the library. In case of accessor failure, error events are
reported at power up. Look for the proposed solution for these
new errors. If no new errors are reported, the 2092 event can be
ignored.
2093 Communication to accessor
controller could not be
established
Reboot the library and if the error persists, replace the accessor
assembly.
2094 An emergency stop condition
was detected in one or more
modules and prevented the
accessor from running the
inventory scan.
v Ensure that all magazines, top or bottom covers and unit locks
are completely inserted and properly locked.
v Insert all open magazines and install all necessary covers and
unit locks before powering on the library.
v Ensure that all modules are powered and have the
interconnect cable properly attached.
2095 Inventory scan failed because of
accessor positioning problem.
Check for obstructions in the horizontal pathway of the accessor
such as a cartridge sticking out or lying on the accessor table.
2096 Initializing a communication
interface on the library
controller failed.
Reboot the library, and if the error persists, replace the library
controller.
Warning error events
An appropriate message is posted on the Operator Control Panel and the Management GUI.
Table 36. Warning events
Event Code Message Text and Description Details and Solution
4000 Drive Sled Fan Speed too low. Ensure that no obstructions are in the fan.
4002 Drive clean request. Clean the drive with an approved cleaning
cartridge.
86 Dell EMC ML3 Tape Library: User's Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC ML3 and is the answer not in the manual?

Dell EMC ML3 Specifications

General IconGeneral
Number of Drives1
CategoryTape Library
Drive TechnologyLTO
Humidity20% to 80% (non-condensing)
Drive TypeLTO Ultrium
Maximum Capacity15 TB (compressed)
Interface6Gb/s SAS
Max Data Transfer Rateup to 750 MB/s (with compression)
Operating Temperature10°C to 35°C
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)

Related product manuals