9.3 Menu Functions for the F-Function
9.3.1 Settings
9.3.1.1 Activate
The system offers a choice between „Activate F-Function“ yes or no.
Make your selection with the cursor keys. Confirm your selection with the ENTER-key and
exit this menu with the ESC-key.
9.3.1.2 Reset Button
The system offers a choice between „Reset by Button“ yes or no.
Make your selection with the cursor keys. Confirm your selection with the ENTER-key and
exit this menu with the ESC-key.
If the reset button is active, then an error reset is possible on the sequence controller, oth-
erwise a reset signal has to be given over the PLC-port.
9.3.1.3 Part Clearance
The system offers a choice between „Part Clearance by Button“ yes or no.
Make your selection with the cursor keys. Confirm your selection with the ENTER-key and
exit this menu with the ESC-key.
If the part clearance by button is active, then the right function key on the sequence con-
troller can make the part clearance, otherwise the part clearance signal has to be given
over the PLC-port.
9.3.1.4 Programs
Use the menu item „Programs“ to change the parameter for the F-function of each individ-
ual program.
First, input the program number, then change the number of screw-joints per part and the
time frame.
9.3.1.4.1 Number of Screw-joints
You may input the number of the required O.K. screw-joints per part.
To change the value, proceed as follows:
Use the left function key „Modify?“
• input value
confirm your input with the ENTER-key
Use the right function-key „Set?“ to activate your setting.