91
11.2.7 Wait for input
Waits for an input signal. Only available for input number 2. Change to the next step will
occur as soon as the input is set.
Parameters:
maximum waiting time
• Input number
11.2.8 Set output
Sets an output. Only available for output number 8.
Parameters:
• output number
time supervision: yes / no
o time until reset
11.2.9 Reset output
Resets an output. Only available for output number 8.
Parameters:
• output number