95-8533
3-49
18.2
EQ25xxARM
24 VDC –
13 14
24 VDC +
11 12
B
6 10
A
5 9
2
+
3
4
+
1
SHIELD
7 8
COM2 COM1
PIRECL
SHIELD
6 3
24 VDC –
4 1
24 VDC +
5 2
B
11 8
A
10 7
CALIBRATE
13
SHIELD
12 9
COM2 COM1
EQ22xxDCU
24 VDC –
13 14
24 VDC +
11 12
B
6 10
A
5 9
4 TO 20 MA IN
2
3
+
4
POINTWATCH
CALIBRATE
1
SHIELD
7 8
COM2 COM1
EQ24xxNE
SHIELD
4 9
24 VDC –
6 7
24 VDC +
5 8
B
11 3
A
10 2
SHIELD
12 1
COM2 COM1
EQ25xxSAM
24 VDC –
13 14
24 VDC +
11 12
B
6 10
A
5 9
OUTPUT 1 –
2
OUTPUT 2 +
3
OUTPUT 2 –
4
OUTPUT 1 +
1
SHIELD
7 8
COM2 COM1
EQ2200IDC EQ3720RM
24 VDC –
13 14
24 VDC +
11 12
B
6 10
A
5 9
CIRCUIT 1 –
2
CIRCUIT 2 +
3
CIRCUIT 2 –
4
CIRCUIT 1 +
1
SHIELD
7 8
COM2 COM1
EQ2100PSM
SHIELD
4 9
24 VDC –
6 7
24 VDC +
5 8
B
11 3
A
10 2
B 2
3
4
C 1
SHIELD
12 1
COM2 COM1
SHUNT P3
AC LINE
N
H
SHIELD
13 3
24 VDC –
11 1
24 VDC +
12 2
B
14 4
A
15 5
SHIELD
16 6
COM2 COM1
SHIELD
13 3
24 VDC –
11 1
24 VDC +
12 2
B
14 4
A
15 5
SHIELD
16 6
COM2 COM1
X3301 / X5200 / X2200 / X9800
Flame Detectors
SHIELD
3 6
24 VDC –
2 5
24 VDC +
1 4
B
5 2
A
4 1
SHIELD
6 3
COM2 COM1
SINGLE SOLENOID
DUAL SOLENOIDS
EQ3700DCIO*
SHIELD
6 3
24 VDC –
5 2
24 VDC +
4 1
B
5 2
A
4 1
SHIELD
6 3
COM2 COM1
P1
P2
P3P4
IN–/OUT+
B B
COMMON
C C
+ SUPPLY
A A
CH 1
CH 5
IN–/OUT+
B B
COMMON
C C
+ SUPPLY
A A
CH 2
CH 6
IN–/OUT+
B B
COMMON
C C
+ SUPPLY
A A
CH 3
CH 7
IN–/OUT+
B B
COMMON
C C
+ SUPPLY
A A
CH 4
CH 8
CONTROLLER
24 VDC –
4 2
24 VDC +
3 1
B
52 49
A
53 50
TxD A
59 56
RxD B
58 55
GND GND
57 54
SHIELD
51 48
COM2 COM1
P1
P7
P9 P8
P4 P5
1+ 5+
5 13
1– 5–
6 14
2+ 6+
7 15
2– 6–
8 16
3+ 7+
9 17
3– 7–
10 18
4+ 8+
11 19
4– 8–
12 20
P2 P3
C
45
NO
46
NC
47
P6
FAULT
GND 5
RXD 2
TXD 3
DB-9
CONNECTION
TO COM PORT
OF PC
DIGITAL INPUTS
C C
21 33
NO NO
22 34
NC NC
23 35
RELAY 5
RELAY 1
C C
24 36
NO NO
25 37
NC NC
26 38
RELAY 6
RELAY 2
C C
27 39
NO NO
28 40
NC NC
29 41
RELAY 7
RELAY 3
C C
30 42
NO NO
31 43
NC NC
32 44
RELAY 8
RELAY 4
SENSOR
POWER
24 VDC
SUPPLY
+
24 VDC
BATTERY
+
H N
AC LINE
POWER
DISTRIBUTION
+
+
+
+
+
++
G2100
P2
P1
* LON AND POWER TERMINALS ALSO
VALID FOR AIM, RM, EDIO.
SEE INDIVIDUAL DEVICE FOR
CHANNEL TERMINALS.
THE DEVICE’S CHASSIS GROUND
TERMINAL SHOULD BE
CONNECTED TO EARTH GROUND.
LS2000
RECEIVER
SHIELD
4 14
24 VDC
3 2
24 VDC +
13 12
B
15 5
A
16 6
CALIBRATE
9
SHIELD
17 8
COM2 COM1
Figure 3-57—A Typical System