Maintenance Manual D900
49-MD900EN05
108
3.10.4.4.Units X 1000
Here you decide whether in accumulative lists, the weight totals are printed in grams or kilograms.
Enabled – It accumulates unit sales in grams. (Default value)
Disabled – It accumulates unit sales in kilograms.
3.10.4.5.Code numbers
You decide how many digits you must enter to seek an article in the scale at normal working mode. The
maximum length an article code may have is 5 digits.
‘0’ – The 6 figures of the article code are used.
‘1’ to ‘6’ – As many figures as in the programmed number are used.
3.10.4.6.Code timeout
It is not necessary to enter all the digits of an article code in order to select it.
The timer is activated each time a key is pressed while an article code is being entered.
After the time has gone past, as entered for this parameter, the article is shown with the code as far as it
has been entered.
Possible values are:
‘NO’ – Timer not activate. Operation as normal.
‘0.5 SEC’ – 0.5 seconds.
‘1 SEC’ – 1 seconds.
‘1.5 SEC’ – 1.5 seconds.
‘2 SEC’ – 2 seconds.
‘2.5 SEC’ – 2.5 seconds.
'3 SEC’ – 3 seconds.
'AUTO SEARCH’ – Active searching in each pulsation.
3.10.4.7.Best Before
The printing mode of the sell by date is established by setting the values of this parameter:
‘ONLY PLU’ – The expiry date of each PLU will be printed.
‘YES - GLOB PREVAIL’ – Permits programming of global expiry date (F5) and global expiry date
prevails.
‘ANY’ – It disables the printing of any type of sell by.
‘SI-PLU PREVAIL’ – Permits programming of global expiry date F5) and the article expiry date
prevails.
3.10.4.8.Draw Control
This parameter allows you to enable or disable the cash drawer check.
‘CONTROL OFF’ – Cash drawer check is disabled.
‘CONTROL ON’ – Cash drawer check is enabled.
‘DETECT ON’ – Draw control detector enabled.
3.10.4.9.Price Increase
It allows you to enable the operation for increasing or decreasing the price. The possible values are:
Disabled
– Disabled increase or decrease in price.
Enabled
– Enabled increase or decrease in the price.
3.10.4.10.Memo amount zero
Disabled
– Does not allow to memorize with Amount Zero.
Enabled
– Allows to memorize with Amount Zero.