EasyManua.ls Logo

Digi TransPort - Page 561

Digi TransPort
813 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configure X.25 parameters
Digi TransPort User Guide 561
PROF command: Load/Save PAD profile
The PROF command stores or retrieves a pre-defined set of X.3 PAD parameters, called a PAD
profile. The information is stored in system file called X3PROF. There are 4 pre-defined profiles,
numbered 50, 51, 90, and 91. Additionally, you can create 4 user PAD profiles, numbered 1 to 4.
Profile 50 is automatically loaded when a PAD is first activated. To load one of the other pre-
defined profiles, use the PROF command, followed by the required profile number. For example:
PROF 90
To create a user PAD profile, use the SET command to configure the various PAD parameters to
suit your application, then use the PROF command in the format:
PROF &nn
where nn is the number of the User PAD profile to be stored, such as 03. Alternatively, you can
use the web interface to edit the parameters directly (Configuration > Network > Legacy
Protocols > X.25 > PADs n-n > PAD n > PAD Settings). The pre-defined profiles (50, 51, 90, 91),
cannot be overwritten and are permanently configured as shown in the following table:
Parameter
Profile
50 51 90 91
11010
20010
3 0 0 126 0
455020
50310
65510
70822
80000
90000
10 0 0 0 0
11 15 15 15 15
12 0 3 1 0
13 0 0 0 0
14 0 0 0 0
15 0 0 0 0
16 8 8 127 127
17 24 24 24 24
18 18 18 18 18

Table of Contents