Configure X.25 parameters
Digi TransPort User Guide 561
PROF command: Load/Save PAD profile
The PROF command stores or retrieves a pre-defined set of X.3 PAD parameters, called a PAD
profile. The information is stored in system file called X3PROF. There are 4 pre-defined profiles,
numbered 50, 51, 90, and 91. Additionally, you can create 4 user PAD profiles, numbered 1 to 4.
Profile 50 is automatically loaded when a PAD is first activated. To load one of the other pre-
defined profiles, use the PROF command, followed by the required profile number. For example:
PROF 90
To create a user PAD profile, use the SET command to configure the various PAD parameters to
suit your application, then use the PROF command in the format:
PROF &nn
where nn is the number of the User PAD profile to be stored, such as 03. Alternatively, you can
use the web interface to edit the parameters directly (Configuration > Network > Legacy
Protocols > X.25 > PADs n-n > PAD n > PAD Settings). The pre-defined profiles (50, 51, 90, 91),
cannot be overwritten and are permanently configured as shown in the following table:
Parameter
Profile
50 51 90 91
11010
20010
3 0 0 126 0
455020
50310
65510
70822
80000
90000
10 0 0 0 0
11 15 15 15 15
12 0 3 1 0
13 0 0 0 0
14 0 0 0 0
15 0 0 0 0
16 8 8 127 127
17 24 24 24 24
18 18 18 18 18