Date and Time parameters
Digi TransPort User Guide 619
Related CLI commands
Entity Instance Parameter Values Equivalent Web Parameter
ntp n driftppm -10000-+10000 Initial Drift Compensation
ntp n precision -10-0 Clock Precision Limit
ntp n inhibit_int Blank,PPP,Ethernet Disable NTP when interface x,y
is out of service
x=Interface type
ntp n inhibit_add 0-255 Disable NTP when interface x,y
is out of service
y=interface number
ntp n server Valid IP address or
hostname, such as
ntp1@timeserver.org
NTP Server
ntp n bcast 0,1 Broadcast Mode
0=disabled
1=enabled
ntp n minpoll 3-14 Poll Interval s1, s2
3=8
4=16
5=32
6=64
7=128
8=256
9=512
10=1024
11=2048
12=4096
13=8192
14=16384
ntp n maxpoll 3-14 Poll Interval s1, s2
See minpoll for values
ntp n burstint 0-255 Startup burst Interval s
seconds
ntp n server2 Valid IP address or
hostname, such as
ntp2@timeserver.org
NTP Server
ntp n bcast2 0,1 Broadcast Mode
0=disabled
1=enabled
ntp n minpoll2 3-14 Poll Interval s1, s2
See minpoll for values