DISPLAY MESSAGES AND FAULT FINDING
27080 Issue 1 August 98 4--9
Ink change needed in less than 2hrs (Not given in extended ink life
printers.)
Ink life is within 2 hours ofexpiry. (Afirstwarning isgivenat24
hours before expiry.)
Fit new ink reservoir.
Ink change needed in less than 24hrs
Ink life is within 24 hours of expiry.
Fit a new ink reservoir.
Ink change needed in less than 300hrs (Extended ink life printers only.)
Inklife iswithin 300hours ofexpiry. (Asecondwarning is given
at 24 hours before expiry.)
Hold new ink reservoir ready for use at 24 hour warnings.
Ink detected on charge electrode
Ink on charge electrode.
Clean charge electrode (see pg. 7--17), restart printer.
Ink hours--to--go data altered
Ink life setting has been altered due to either ink being changed
or ink life setting value adjustment.
Check authorisation for change.
Ink heating failed
Ink heating system has failed.
Check heater connections and check thermistor.
Ink level sensor input error
Failure at input to sensor.
Check sensor connections. If fault persists, call Domino
Service.
Ink pressure loss
Pressure loss due to leakage, pump failure or transducer failure.
Check for leaks. Check electrical connections, pump and
transducer operation.
Ink temperature high
Ink temperature is outside control system limits.
Ensure printer environment is within specification.