Programming
134 Service Instructions 867-M PREMIUM - 03.0 - 05/2017
3. Select the desired option – see the table – with the ▲/▼ buttons.
4. Press the OK button to confirm the selection.
The reset is carried out without any further query and without a con-
firmation message.
Options for resetting the data
20.10 Data transfer (Data Transfer) submenu
Use this submenu to transfer data between the machine – or more precisely
the control – and a USB key. Various options are available for the data trans-
fer, which are explained in the subchapters.
The menu is divided into the following submenus:
Important
It is permitted only to use USB keys bought from Dürkopp Adler.
20.10.1 Setting the All data (All Data) parameter
All data – i.e. parameter settings, programs, and calibration values – are
transfered to the USB key or the control.
To transfer all data:
1. Plug the USB key into the socket (1) on the control (2).
Menu item Setting options
Reset data All parameters are reset to the factory settings; this does not apply
to the programs and the calibration values.
Reset programs All created programs are erased.
Reset Calibr. All calibration values are reset to the factory settings.
Reset all All parameters, programs, and calibration values are reset to the
factory settings.
Parameter Explanation Reference
All Data All data p. 134
Only Data Only data p. 136
Programs Programs p. 137