Programming Commander DELTA
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 99
First bartack section
The 1
st
section of the bartack can be 
programmed with a different number of 
stitches. All subsequent sections have 
the preset number of stitches from the 
settings for the start bartack.
On/Off
Number of stitches
Value range
01 - 50
Last bartack section
The last section of the bartack can be 
programmed with a different number 
of stitches. All previous sections have 
the preset number of stitches from the 
settings for the end bartack.
On/Off
Number of stitches
Value range
01 - 50
Invert bartack direction
Normally, a bartack starts either with 
the sewing direction (forwards – even 
number of sections) or against the 
sewing direction (backwards – odd 
number of sections), depending on 
the number of sections.
Setting this parameter inverts the 
sewing direction of the bartack.
Value range
On/Off
Icon Parameter Setting