5.8.7 Setting the Segment parameters
There are various options for setting the parameters in the
segment. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Icon Parameter Setting
Seam Parameter
Stitch length Value range
00.0 - 12.0 [mm]
(depending on the sewing equipment
and the subclass)
Needle thread tension Value range
01 - 99
Sewing foot pressure Value range
01 - 20
Sewing foot stroke Value range
1.0 9.0 [mm]
Seam length in segment
or
Number of stitches in segment
You can set the active option at the
Technician level Machine config-
uration > Mode segment size.
The s.p.m. option is set at the factory.
The display remains after the thread
has been cut, while counting/measur-
ing will begin when sewing starts
again.
Max. Speed
It is possible to reduce the maximum
sewing speed at this point. The value of
the maximum sewing speed can be set in
the software at the Technician level.
Value range
0050 3800 [rpm]
(depending on subclass)
Needle position
Needle position at sewing stop.
Value range
On/Off
Sewing foot lift at stop Value range
On/Off