Operation
24 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
4.4.2 On 2-needle machines
Fig. 5: Inserting/changing the needle
To change the needle in a 2-needle machine:
1. Turn the handwheel until the needle bar (1) has reached
the upper end position.
2. To change the right needle, loosen the right screw (2).
3. To change the left needle, loosen the left screw (2).
4. Pull the needles downwards out of the needle holder (4).
5. Insert each new needle into the corresponding hole of
the needle holder (4) until it reaches the stop.
Important
Align the new needles in such a way that the grooves (3) face the
hook (4). As viewed from the user side, the groove (3) of the left
needle must point to the left, while the groove (3) of the right needle
must point to the right.
6. Tighten the screw (2).
(1) - Needle bar
(2) - Screw
(3) - Groove
(4) - Needle holder