Setup
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 167
7.14.2 Setting the operating pressure
Proper setting
Refer to the Technical data ( p. 195) chapter for the permissi-
ble operating pressure. The operating pressure cannot deviate
by more than ± 0.5 bar.
Fig. 83: Setting the operating pressure
To set the operating pressure:
1. Pull the pressure controller (1) up.
2. Turn the pressure controller until the pressure gage (2)
indicates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3. Push the pressure controller (1) down.
NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to
the machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
(1) - Pressure controller (2) - Pressure gage