Programming Commander DELTA
112 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Gap (2
nd
value)
The 2
nd
value for the gap can be
switched on using a button on the push
button panel or the tile on the control
panel.
Value range
01.0 45.0 [mm]
Program Cycle
Next program
A subsequent program can be defined.
Input via program number.
Program Cycle
The program is executed as a loop,
which is useful, for instance, for
ornamental stitch seams.
You select the start segment and the
end segment from a program and
define how often you wish the selected
segments to be sewn.
On/Off
Start Segment
Value range 00 30
(0 = the cycle starts with the first
segment)
End Segment
Value range 00 30
(0 = the cycle ends with the last
segment)
Repetitions
Value range 00 99
(0 = the cycle continues until the next
segment is activated manually)
Main Parameter
Needle thread clamp
The needle thread clamp is closed at
the 1
st
stitch of the seam to ensure that
the needle thread lies on the underside
of the sewing material
Value range
On/Off
Bobbin monitor mode (see p. 115)