Maintenance measures - 250 h
4812164901_A.pdf2022-11-14
Maintenance measures - 250 h
Every 250/750/1250/1750..... hours of operation
(every 3 months)
Park the roller on a level surface.
The battery must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Park the roller on a level surface.
The battery must be switched off and the
parking brake activated when checking or
adjusting the roller, unless otherwise specified.
Ensure that the hood is fully open when work is
being carried out under it
Ensure that the hood is fully open when work is
being carried out under it
Hydraulic oil cooler - Cleaning
Fig. Engine compartment
1. Hydraulic fluid cooler
1
Clean the cooling flanges of the hydraulic oil cooler,
preferably with compressed air.
Do not use a high-pressure washer – the machine is
electrically powered and has electrical components.
When working with compressed air, use the
following protective equipment:
When working with compressed air, use the
following protective equipment:
Safety glassesSafety glasses
Protective glovesProtective gloves
Ear protectorsEar protectors
103