Maintenance - 1000h
4812164901_A.pdf 2022-11-14
Hydraulic reservoir - Check/venting
Fig. Beneath hood, right-hand side
1. Hydraulic oil tank cap
1
Unscrew and make sure that the reservoir cap is not
blocked. Air must have unobstructed passage through
the cap in both directions.
If blocked in either direction, clean with a little diesel oil
and blow with compressed air until unblocked or
replace the cap with a new one.
When working with compressed air, use the
following protective equipment:
When working with compressed air, use the
following protective equipment:
Safety glassesSafety glasses
Protective glovesProtective gloves
Ear protectorsEar protectors
Fig. Hydraulic reservoir
1. Sight glass
1
Check the hydraulic oil level in the sight glass (1) and
top off where necessary. See under the heading
‘Every 10 hours of operation’.