Maintenance - 2000h
4812164901_A.pdf 2022-11-14
Hydraulic reservoir - fluid change
Use an external drainage pump when
draining/emptying the hydraulic reservoir.
Fig. Hydraulic tank
1. Hydraulic oil tank cap
1
Risk of burn injuries when draining hot oil. Use the
following protective equipment:
Risk of burn injuries when draining hot oil. Use the
following protective equipment:
Safety glassesSafety glasses
Protective glovesProtective gloves
Unscrew the hydraulic oil tank cap (1). Place the
pump's suction hose in the filler/drain outlet in the
hydraulic tank. Place the other hose in a container.
Use a receptacle that holds more than 15 liters (4
gallons).
Use a receptacle that holds more than 15 liters (4
gallons).
Start the pumpen so that it sucks out the fluid from the
tank.
Check that the hose to the pump reaches the bottom
of the hydraulic reservoir to ensure that as much of the
fluid as possible is drained.
Save the oil and hand in to an
environment-friendly waste disposal station.
Save the oil and hand in to an
environment-friendly waste disposal station.
Fill up to the correct level using the recommended
hydraulic oil. Replace the hydraulic oil tank cap and
wipe clean the hydraulic tank.
Change the hydraulic fluid filter, see under heading
'Every 1000 hours of operation'.
Run the engine and operate the various hydraulic
functions. Check the level in the tank and top up as
required.