Fault description Cause Remedy
0001 = Output triggered
1310 Output valve vibration high amplitude, Y 57 Display value = output voltage in Volt
Voltage at output Display value = output voltage in Volt
1311 Output valve vibration high amplitude, Y 57 Display value = output current in Amperè
Current at output Display value = output current in Amperè
1312 Output valve vibration high amplitude, Y 57 0000 = Output not triggered
0001 = Output triggered
Logic level of control 0000 = Output not triggered
0001 = Output triggered
Fault descrip-
tion
Cause Remedy
1400 Input signal L from generator regulator 12 V > Generator stopped
Ground, 0 V > Generator running
1401 Input oil pressure switch, B 06 12 V > No oil pressure
Ground, 0 V > Oil pressure
1402 Input limit switch engine speed solenoid,
Aux
12 V > Solenoid retracted
0V Ground > Solenoid not in end position
1405 Input inclination sensor, B 56 12 V > Inclination less than 45°
0V Ground > Inclination higher than 45°
1409 Activation input, cable remote control, S
101
12 V > Operating mode cable remote control
1410 Activation input, radio remote control, S
101
12 V > Operating mode wireless
Fault
description
Cause Remedy
5010 Engine speed Display value = 1/min
5020 Engine oil pressure, B 06 0000 = No engine oil pressure
0001 = Engine oil pressure OK
Shows status of input engine oil
pressure
0000 = No engine oil pressure
0001 = Engine oil pressure OK
5030 Inclination sensor, B 56 0000 = No signal, machine inclined more than 45°, or
switch defective
Inputs logic and power module
Diesel engine, machine electrics
Appendix – Input codes for BLM control
D.ONE
183