Fault
description
Cause Remedy
0001 = OK, inclination of machine less than 45°
Shows the switching state of the
inclination switch
0000 = No signal, machine inclined more than 45°, or
switch defective
0001 = OK, inclination of machine less than 45°
5040 Output bia winding of shut-down
solenoid, Y 13
Display value = output voltage in Volt
Voltage at output Display value = output voltage in Volt
5041 Output bia winding of shut-down
solenoid, Y 13
Display value = output current in Amperè
Current at output Display value = output current in Amperè
5042 Output bia winding of shut-down
solenoid, Y 13
0000 = Output not triggered
0001 = Output triggered
Logic level of control 0000 = Output not triggered
0001 = Output triggered
5050 Output relay K 114, engine speed
solenoid
Display value = output voltage in Volt
Voltage at output Display value = output voltage in Volt
5051 Output relay K 114, engine speed
solenoid
Display value = output current in Amperè
Current at output Display value = output current in Amperè
5052 Output relay K 114, engine speed
solenoid
0000 = Output not triggered
0001 = Output triggered
Logic level of control 0000 = Output not triggered
0001 = Output triggered
5055 Enable parameter change ECO-
mode
5056 Confirm parameter change ECO-
mode
Subsequently switch off the ignition!
5057 ECO-mode off Enter code number 5055 first!
5058 ECO-mode on Enter code number 5055 first!
5059 Display of ECO-mode setting 0 = ECO-mode off
1 = ECO-mode on
5060 Output relay K 11, potential
changeover
Display value = output voltage in Volt
Voltage at output Display value = output voltage in Volt
5061 Output relay K 11, potential
changeover
Display value = output current in Amperè
Appendix – Input codes for BLM control
D.ONE
184