EasyManua.ls Logo

Dynapac F6C - Vibration Acting on the Entire Body; Vibrations Acting on Hands and Arms; Electromagnetic Compatibility (EMC)

Dynapac F6C
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B 22
B F6C.GB 22-22 0504
6.4 Vibration acting on the entire body
When the machine is used properly, the weighted effective acceleration values at the
driver’s seat of a
w
= 0.5 m/s
2
according to the draft of prEN 1032-1995 are not ex-
ceeded.
6.5 Vibrations acting on hands and arms
When the machine is used properly, the weighted effective acceleration values at the
driver’s seat of a
hw
= 2.5 m/s
2
according to the draft of prEN 1033-1995 are not ex-
ceeded.
6.6 Electromagnetic compatibility (EMC)
The following limit values are observed according to the stipulations of the EMC Di-
rective 89/336/EEC/08.95:
- Interference emission according to DIN EN 50081-1/03.93:
< 40 dB µV/m for frequencies of 30 MHz - 230 MHz measured at a distance of 3 m
< 47 db µV/m for frequencies of 20 MHz - 1 GHz measured at a distance of 3 m
- Interference immunity against electrostatic discharge (ESD) according to DIN EN
61000-4-2/03.96:
The paver finisher did not show any discernible reactions to contact discharges of
± 4 KV and to air discharges of ± 8 KV.
The modifications according to test criterion „A“ are adhered to, i.e. the paver fin-
isher continues to work without malfunction during the test.
Electrical or electronic components and their arrangement may only be modified after
written approval from the manufacturer has been obtained.