E 4
E F6C.GB 4-6 0504
2.4 Auger extension
Depending on the type of screed, the most diverse working widths can be reached.
Auger and screed extension must match.
Refer to the appropriate chapter „Set-up and modification“ in the Bohlen-Betriebsan-
leitung:
– Screed extension chart,
– Auger extension chart.
To attain the desired working width, the corresponding screed extensions, augers,
tunnel plates or cut-off shoes must be mounted.
For widths of more than 3.00 m, the auger should be fitted with extension parts on
both sides to improve material distribution and to reduce the wear.
The diesel engine must be switched off whenever work is performed on the auger.
Danger of injuries!