D 24
D F6C.GB 24-50 0504
Conveyor limit switch (paddle) (71)
The conveyors should stop when the
material has roughly reached the area
below the auger tube.
Each conveyor is equipped with a limit
switch, which determines the point at
which the conveyor drive is switched off.
Setting the deactivation point:
- Loosen threaded pin (A) and turn the
excenter shaft (B) to the desired deac-
tivation point.
- Tighten the threaded pin (A) again to
secure the excenter shaft.
Sensorl_F6.jpg/Sensor2_F6.jpg
71
A
B