Dynapac F6C - Check List for the Machine Operator

Dynapac F6C
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D 32
D F6C.GB 32-50 0504
Check list for the machine operator
Check! How?
Emergency stop button
- on the operating panel
Push in the button.
The diesel engine and all running drives must stop
immediately.
Steering
The paver finisher must immediately follow every
steering wheel movement in a precise manner.
Check straight running.
Horn
- on the operating panel
- on both remote controls
Briefly press the horn button.
The horn must sound.
Lighting
Switch on with the ignition key, walk around the
paver finisher to check and switch off again.
Screed hazard flasher
(with vario screeds)
With the ignition switched on, press the switches
for extending/retracting the screed parts.
The warning lamps must flash.
Gas heater system (
&
):
- Bottle holder
- Bottle valve
- Pressure reducer
- Hose rupture protection
- Closing valves (burners)
- Main shut-off valve
- Connections
- Indicator lamps of the switch box
Check:
- Secure seat
- Cleanliness and tightness
- Working pressure 1.5 bar
- Function
- Function
- Function
- Tightness
- All lamps must light up when the system is
switched on
Screed covers and walkways
Hinged walkway plates must be swung down.
Check that the side shields, the side plates and the
covers are securely seated.
Screed transport safeguard
When the screed is raised, the transport safe-
guards beneath the lifting cylinder retaining bolts
must be able to pivot.
Hopper transport safeguard
When the hopper is closed, it must be possible to
push the bolts into the relevant bores in the vehicle
frame.
Protective roof
The locking bolts on both sides must be located in
the intended bore.
Miscellaneous:
- Engine hoods
- Side flaps
Check that the hoods and flaps are securely
seated.