EasyManua.ls Logo

Edwards EV1000

Edwards EV1000
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14-2
EV1000 Clinical Platform NI Advanced Features
applications. Continuously monitored and calculated param-
eters with the EV1000 Clinical Platform NI can be sent to the
enterprise application:
Physiological Alarms and Device Faults
The EV1000 system can send physiological alarms and
device faults to configure HIS. Alarms and faults can be sent
to one or more configured HIS. Statuses of individual alarms
including change in states are sent out to the enterprise appli-
cation.
For more information on how to receive access to HIS
Connectivity, contact your local Edwards Representative or
Edwards Technical Services.
Goal Positioning Screen
The Goal Positioning Screen allows the user to monitor and
track the relationship of two key parameters by plotting them
against each other on an XY plane.
A single, pulsating blue dot represents the intersection of the
two parameters and moves in real time as parameter values
change. The additional circles represent the historical
parameter trend with the smaller circles indicating older data.
The green target box represents the intersection of the green
parameter target zone. The red arrows on the X and Y axis
represent the parameter alarm limits.
If not activated, the user must first enable the screen via the
Monitoring Screen Navigation Bar Menu.
1 Touch the Settings button.
2 Touch Monitor Settings.
3 Touch Advanced Features.
The platform requires the user to enter a password to enable
the Advanced Features. Please contact your local Edwards
Representative for more information on enabling these
Advanced Features.
Once the screen is enabled, the user can access the screen via
the Monitor Screen Selection button.
1 Touch the Monitor Screen selection button.
2 Touch the circled number 2, 3, or 4 representing the
number of key parameters to be displayed on the
monitoring screen.
3 Touch the Goal Positioning Screen button.
Parameter Selection
The user can select the parameters for the X
and Y axis.
1 Touch outside the globe on the top
parameter. The currently selected Y
axis parameter appears highlighted in
color and other displayed parameters are
outlined in color.
2 If the currently selected Y-axis
parameter is not desired, touch which
parameter should appear on the Y axis.
The user can change the X axis by applying the same steps to
the 2nd parameter globe.
Trend, Target and Alarm Customization.
To adjust the time interval between
the historical trend circles, touch
the trend interval icon displayed on
the screen.
To turn the trend interval icon On/Off, touch within the X/Y
plane.
To adjust the green box and red arrows, access the target
menu by touching inside the corresponding parameter globes.
To adjust the scale of the X or Y axis, touch along the corre-
sponding axis.
If the current intersection of parameters moves outside the
scale of the X/Y plane, a message will appear indicating this
to the user.
Figure 14-3 Goal Positioning Screen

Table of Contents

Other manuals for Edwards EV1000

Related product manuals