EasyManua.ls Logo

Electrolux E23CS75DSS0 - Water in the Refrigeration System; Vacuum Pump Maintenance

Electrolux E23CS75DSS0
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
Section E - R-134a Service Information
Attheearlieststageofdevelopmentworkon
R-134a,testswerecarriedoutonadifferenttypeof
syntheticoilknownasPoly-AlkalineGlycol(PAG).
Thisoilisalsousedincertainairconditioning
systemsforcars.PAGandEsteroilDONOTmix
withoneanother.Serviceequipmentusedfor
R-134a/Esteroilmustnotcomeintocontactwith
PAG.
Water In The Refrigeration
System
Eveninverysmallquantities,waterinany
refrigerationsystemcancausethefollowing
problems:
•Iceplugsincapillarytubes.
•Copperplatingincompressor.
•Reactionswithorganicmaterialsinsystems.
•Corrosionofmetals.
R-134aandEsteroilwillaggravatetheproblem
ofwaterintherefrigerationsystem.Esteroilmay
reactwithwatervaporandishydroscopic(itwill
absorbwaterifitcomesincontactwithhumidair).
WaterisalsomoresolubleinR-134athanR-12.
Tominimizethewatercontentwheneverservice
workisperformed,therefrigerationsystemshould
alwaysbethoroughlyevacuatedthroughprocess
tubeadaptorsonboththehighandlowsidesof
thesystem.Evacuationmustbeforaminimum
of30minutestoatleasta29.9inch(500micron)
vacuum.
Toachievetherequired29.9inch(500micron)
vacuum,aproperlymaintainedtwo-stagevacuum
pumpingoodconditionisrequired.Atwostage
pumpcanreachadeepervacuumthanasingle
stagebecausetheexhaustfromtherstpumping
stageisdischargedintothesecondpumpingstage.
Thismeansthesecondstagebeginspumpingata
lowerpressuresoalowerultimatevacuumcanbe
achieved(See2-StageVacuumPump,FigureE3).
VACUUM CHART
Vacuum
Inches Hg.
Microns
Boiling Point
of Water °F
28.940 25000 77.9
29.530 10000 52.0
29.832 4600 32.0
29.882 1000 1.0
29.901 500 -11.2
29.915 150 -32.8
29.917 100 -38.2
29.919 50 -49.0
Vacuum Pump Maintenance
Itisabsolutelyessentialtomaintainyourvacuum
pumpaccordingtothemanufacturer’sinstructions
includingrequiredoilchangesattherecommended
intervals.Vacuumpumpoilshouldalwaysbe
changedafterevacuatingacontaminatedsystem.
Vacuumpumpperformanceshouldbechecked
periodicallywithamicrongauge.
Vacuumpumpsuppliersmayormaynot
recommendchangingthevacuumpumpoiltothe
sametypethat’sinthesystembeingevacuated.
Somemanufacturersmayrecommendavacuum
pumpthat’sdedicatedtoR-134asystems.
Robinairhasstatedthattheircurrentand
discontinuedvacuumpumpmodels,usingmineral
oilcurrentlyspeciedforuseintheirvacuum
pumps,canbeusedtoevacuateR-134a/Esteroil
systems.Robinairalsostatesthatitisacceptable
toalternatebetweenevacuatingR-12/mineraloil
andR-134a/Esteroilsystemswithoutadversely
effectingthevacuumpump’sperformance.
Forotherbrandsofvacuumpumps,checkwiththe
manufacturerforrestrictionsandguidelineswhen
usingwithR-134a.
2-Stage Vacuum Pump
Figure E3

Table of Contents

Related product manuals